3 SPECIFICATIONS AND FUNCTIONS
3.5.3 List of input/output signal details
The details of each AD75 external device connection connector (for 1 axis) signal are
shown below.
Signal name
Common
Manual pulse generator
(B phase –)
Manual pulse generator
(A phase –)
Manual pulse generator
(B phase +)
Manual pulse generator
(A phase +)
Common
Deviation counter clear common
Zero point signal common
Zero point signal (+5V)
Zero point signal (+24V)
Pulse sign
Pulse output (differential driver –)
Pulse sign
Pulse output (differential driver +)
Pulse sign common
Pulse output common
(Open collector)
Pulse sign
Pulse output (Open collector)
External start signal
Speed/position changeover signal
Stop signal
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pin No.
•
36
Common for near-point dog signal, upper/lower limit, stop signal,
35
speed/position changeover signal, and external start signal.
•
Input the pulse signal from the manual pulse generator A phase and B
phase.
•
If the A phase is advanced more than the B phase, the positioning
28
address will increase at the rising edge and falling edge of each phase.
27
•
If the B phase is advanced more than the A phase, the positioning
address will decrease at the rising edge and falling edge of each phase.
[When increased]
A phase
10
B phase
9
Positioning
+1+1+1+1+1+1+1+1
address
26
•
Common for drive unit READY and in-position.
23
•
Common for deviation counter clear.
25
•
Common for zero point signal (+5V) and zero point signal (+24V).
•
Input the zero point signal for machine zero point return.
Use the zero point signal of the pulse encoder or the like.
24
•
Use this signal when the zero point return method is the stopper method
6
and the machine zero point return complete is input from an external
source.
•
The zero point signal is detected at turning from OFF to ON.
22
21
•
Output the positioning pulses and pulse sign for the differential driver
compatible drive unit.
4
3
20
19
•
Output the positioning pulses and pulse sign for the open collector
compatible drive unit.
2
1
•
Use as the positioning start, speed change request and skip request
input signal from an external source.
16
•
Set which function to use the external start signal with in " Pr.43
External start function selection".
•
Input the control changeover signal for the speed/position changeover
15
control.
•
Input when positioning is stopped.
•
When this signal turns ON, the AD75 will stop the positioning being
14
executed.
After that, even if this signal turns from ON for OFF, the system will not
start.
3 - 19
MELSEC-A
Signal details
[When decreased]
A phase
B phase
Positioning
-1 -1 -1 -1 -1 -1 -1 -1
address