3 SPECIFICATIONS AND FUNCTIONS

3.5.3 List of input/output signal details

The details of each AD75 external device connection connector (for 1 axis) signal are
shown below.
Signal name
Common
Manual pulse generator
(B phase –)
Manual pulse generator
(A phase –)
Manual pulse generator
(B phase +)
Manual pulse generator
(A phase +)
Common
Deviation counter clear common
Zero point signal common
Zero point signal (+5V)
Zero point signal (+24V)
Pulse sign
Pulse output (differential driver –)
Pulse sign
Pulse output (differential driver +)
Pulse sign common
Pulse output common
(Open collector)
Pulse sign
Pulse output (Open collector)
External start signal
Speed/position changeover signal
Stop signal
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pin No.
36
Common for near-point dog signal, upper/lower limit, stop signal,
35
speed/position changeover signal, and external start signal.
Input the pulse signal from the manual pulse generator A phase and B
phase.
If the A phase is advanced more than the B phase, the positioning
28
address will increase at the rising edge and falling edge of each phase.
27
If the B phase is advanced more than the A phase, the positioning
address will decrease at the rising edge and falling edge of each phase.
[When increased]
A phase
10
B phase
9
Positioning
+1+1+1+1+1+1+1+1
address
26
Common for drive unit READY and in-position.
23
Common for deviation counter clear.
25
Common for zero point signal (+5V) and zero point signal (+24V).
Input the zero point signal for machine zero point return.
Use the zero point signal of the pulse encoder or the like.
24
Use this signal when the zero point return method is the stopper method
6
and the machine zero point return complete is input from an external
source.
The zero point signal is detected at turning from OFF to ON.
22
21
Output the positioning pulses and pulse sign for the differential driver
compatible drive unit.
4
3
20
19
Output the positioning pulses and pulse sign for the open collector
compatible drive unit.
2
1
Use as the positioning start, speed change request and skip request
input signal from an external source.
16
Set which function to use the external start signal with in " Pr.43
External start function selection".
Input the control changeover signal for the speed/position changeover
15
control.
Input when positioning is stopped.
When this signal turns ON, the AD75 will stop the positioning being
14
executed.
After that, even if this signal turns from ON for OFF, the system will not
start.
3 - 19
MELSEC-A
Signal details
[When decreased]
A phase
B phase
Positioning
-1 -1 -1 -1 -1 -1 -1 -1
address