7
SEQUENCE PROGRAM USED FOR POSITIONING
CONTROL
7
- 29
7.5 Program Details
7.5.3 Start program
POINT
For positioning control and OPR control, multiple axes can be started
simultaneously. In this case, turn ON the positioning start signal (Y8 to YA) of the
target axes within the same scan.
(However, after multiple axes have been started simultaneously, they cannot be
stopped simultaneously.)