Figure 27
Typical placement of NTAK75 (Vertical cabinet expansion)
The center line of the NTAK75 for the Expansion Cabinet may be placed a
maximum of 2.5 ft (760 mm) to the left of the center line of the cabinet. The
center line of the NTAK75 for the Main Cabinet may be placed a maximum
of 2 ft (610 mm) to the right of the center line of the cabinet. These distances
are based on the cabinets being mounted at the recommended heights, as
shown in the diagram above, for the vertical mounting configuration.
System and site requirements Page 69 of 408
Option 11C
Planning and Installation Guide