Installing and connecting SDI and ethernet ports Page 231 of 408
Procedure 37
Connecting the Ethernet cable
1
Insert the 50-pin end of the cable into the cable connector on the
left side of the retaining bar as shown below.
2
Route the cable through the fifth cable groove from the left side.
The ethernet cable is a 50-pin amphenol to 15-pin AUI adaptor cable
(Part number for ethernet cable NTDK27 A06030723). This provides a
standard MAU attachment point.
Note: A jumper block located on connector J7 (near the Fiber 2
connector) (see Figure 92 on page 230 and the following figure) on the
component side of the NDK20EA SSC card must be in place for the
Ethernet connection to function. The NDK20EA SSC card is normally
shipped with the plug installed. If the Ethernet connection does not
appear to function properly, check the jumper plug to make sure that it
is installed.
Figure 93
Connector J7
3
If not previously done, configure the ethernet port in software as
described in Maintenance (553-3001-511).
J7 Jumper Plug
Option 11C
Planning and Installation Guide