Nortel Meridian 1 Option 11C Planning And Installation Manual page 178

Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 178 of 408
Installing and connecting cross-connect terminals to cabinets
Figure 75
Cable connectors in a system cabinet
Location of the
AUX cable
553-3021-210
Standard 7.00
Connector and cables to
cross-connect terminal
3
Route the cables down through the opening at the bottom of each
cabinet.
4
Replace the retaining bar when you have connected all the cables
to the cabinet.
5
Terminate all the 25-pair cables installed at the cross-connect
terminal.
Label all the cables at the cross-connect terminal blocks according to
the card slot allocation plan.
6
Install the AUX cable on the lower 9-pin connector located on the
left side of the connector area in the lower part of each cabinet.
Terminate the AUX cable at the cross connector located on the left
side of the connector according to Figure on page 178.
January 2002
Retaining bar