Installing power fail transfer units
Installing the PFTU
553-3021-210
Standard 7.00
Consult the equipment layout plan to determine where the PFTU should be
located.
Procedure 23
Installing the PFTU
1
Mount the PFTU on the wall near the system cross-connect
terminal and secure it with four screws.
2
Install an NE-A25B-type 25-pair cable from connector J1 on the
faceplate of the PFTU to its assigned location at the
cross-connect terminal.
3
Label the pairs of the J1 cable on the cross-connect terminal
block as shown in Figure 76 on page 182.
Figure 76
J1 cable labeling
4
Connect the PFTU power and control connections to the AUX
cable (see Figure 77 on page 183) from the cabinet. Refer to
Table 77, "Auxiliary port location," on page 183.