g) Install the remaining circuit cards. Refer to "Installing the circuit
cards" on page 187.
h) Install the cross-connect terminal and Cables. Refer to
"Installing and connecting cross-connect terminals to cabinets"
on page 169.
i)
Install the power fail transfer units (PFTUs) if provided. Refer
to "Installing power fail transfer units" on page 181.
j)
Connect the SDI and Ethernet interfaces. Refer to "Installing
and connecting SDI and ethernet ports" on page 213
3
For IP connectivity, refer to Procedure 2, step 3 through step 6, on
page 103 - page 104.
4
Power up the the main and expansion cabinets. Refer to
Procedure 2, Step 7 on page 105.
5
Install the System Software on the IP Expansion Cabinet (not
required for fibre expansion cabinets). Refer to "System software
installation" on page 233.
6
Install (if not previously installed) and activate the telephones.
Refer to "Connecting the telephones" on page 247.
7
Connect the trunks to the system as described in "Connecting
the trunks" on page 277
8
Perform a system backup, using LD 43.
9
Install any remaining equipment, such as external alarms (Refer
to "Connecting an external alarm" on page 307).
10
Replace all drip trays and cabinet covers.
—————————— End of Procedure ——————————
Procedure 4
Reconfiguring existing cabinets to accommodate an additional
expansion cabinet
Under certain circumstances it is necessary to rearrange cabinet connections
and/or configurations. Two scenarios are described.
Installation Procedures Page 109 of 408
Option 11C
Planning and Installation Guide