Connecting 500/2500-Type Telephones With A Pftu - Nortel Meridian 1 Option 11C Planning And Installation Manual

Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 252 of 408
Connecting the telephones

Connecting 500/2500-type telephones with a PFTU

553-3021-210
Standard 7.00
• Table 44, "Expansion Cabinet 2 Default DN assignments," on
page 265
• Table 45, "Expansion Cabinet 3 Default DN assignments," on
page 267
• Table 46, "Expansion Cabinet 4 Default DN assignments," on
page 268
The telephone can now be activated as described in "Activating
telephones" on page 269.
Note: All the following tables show the default DNs.
Procedure 42
Connecting 500/2500-type telephones with a PFTU
1
Locate the telephone terminations on the cross-connect terminal.
2
Connect one end of the cross-connect wire to the leads of the
telephone.
3
Locate the PFTU connections (unit PFT 1 through PFT 5)
assigned to this telephone at the cross-connect terminal.
Refer to Table 39 on page 261 and Table 40 on page 262.
4
Connect the other end of the cross-connect wire to the pair
assigned to the telephone on the PFTU.
5
Connect a second cross-connect wire to the pair assigned to the
line card on the PFTU.
6
Locate the line card terminations on the cross-connect terminal.
Refer to Table 37 on page 258 for the Main cabinet and Expansion
cabinets 1 and 2.
Refer to Table 38 on page 259 for Expansion cabinets 3 and 4.
7
Connect the other end of the cross-connect wire to the assigned
TN terminal block.
Default DN assignments are given in the following Tables:
• Table 42, "Main Cabinet Default DN assignments," on
page 263
January 2002