Nortel Meridian 1 Option 11C Planning And Installation Manual page 112

Hide thumbs Also See for Meridian 1 Option 11C:
Table of Contents

Advertisement

Page 112 of 408
Installation Procedures
Figure 38
Option 11C Mini EMC grounding clip location
100BaseT cables
secured with a cable tie
553-3021-210
Standard 7.00
Figure 39 on page 113 shows an example "mix-and-match" configuration in
which an Option 11C Main cabinet uses both fiber and IP cabling to connect
two Option 11C Expansion cabinets and one Option 11C Mini Expansion
chassis.
Note: Figure 39 on page 113 is only an example of one of many possible
configurations using Option 11C cabinets and Option 11C Mini chassis.
The SSC card in the Option 11C Main cabinet has one dual-port Fiber
daughterboard installed in the top connector and one single-port IP
daughterboard installed in the bottom connector. The dual-port Fiber
daughterboard in the top connector provides card slots 11-20 and 31 to 40.
The single-port IP daughterboard in the bottom connector provides card slots
21-30.
January 2002
Grounding Clip