Page 94 of 226
Upgrading Small System hardware
Server card installation
NN43041-464
Standard 05.04
The following procedure describes how to install the Server card in a Media
Gateway.
MG 1010 slots 22 and 23 require the NTDW53 CP DC card, or NTDW99
CP PM card with metal faceplate. MG 1000E and MG 1010 slots 1-10
support NTDW53 CP DC cards, NTDW61 CP PM cards, and NTDW99
CP PM cards.
If you require more than two Server cards in a MG 1010, you
can install additional Server cards in slots 1-10.
The CP MG card occupies slot 0 in a Media Gateway.
Ensure that the Dip Switch (S5) is set to position 1 if using the CP PM as a
Call Server or position 2 if using the card as a CP PM Signaling Server.
Procedure 8
Installing the CP PM or CP DC card
1
Ensure that the security dongle (the one that comes as part of the
software kit) is inserted on the Server card.
Note 1: This first step is applicable only when the Server card is used as
a Call Server.
Note 2: For CP PM only, remove the retainer clip from the FMD slot
when the card is used as a Signaling Server. The clip must be removed
to prevent it from shorting out adjacent cards.
2
Ensure that the FMD is correctly inserted and locked in place.
3
Insert the Server card.
•
Slide the Server cardinto Slot 1 (or higher)
or chassis
.
•
Slide the Server card into Slot 22 or 23 of the MG 1010 chassis.
4
Lock the card into the faceplate latches.
December 2011
of the MG 1000E cabinet