Removing The Ssc Card - Avaya CS 1000E Upgrade Procedures

Hide thumbs Also See for CS 1000E:
Table of Contents

Advertisement

Page 150 of 226

Removing the SSC card

NN43041-464
Standard 05.04
Upgrading a CP PII or CP PIV to CP PM
The following rules apply to the placement of the CP PM cards in an IPE
module with MG XPEC card:
The CP PM Call Server cannot be placed in the controller slot. The
controller slot is reserved for the MG XPEC.
The CP PM Call Server can be placed inslots 0 through 7 on the left and
right side or the IPE module. You renumber the IPE module right side
slots 8 to 15 as 0 to 7 with a new label included in the MG XPEC cable
kit. CP PM cards in an IPE module require the NTAK19EC for serial
connections.
If utilizing the Campus Redundancy High Availability (HA) Call Server
option, place the two CP PM Call Servers in separate IPE modules to
allow for increased survivability. HA is not supported on a Co-resident
Call Server and Signaling Server system.
For more information about converting an NT8D37 IPE module into Media
Gateways with an NTDW20 MG XPEC card, see Avaya Communication
Server 1000M and Meridian 1 Planning and Engineering (NN43021-220).
For information about the installion and cabling of an MG XPEC card, see
Avaya Communication Server 1000E: Installation and Commissioning
(NN43041-310).
Procedure 19
Removing the SSC Card
1
Power down the system.
2
Unlatch the SSC card.
December 2011