Avaya CS 1000E Upgrade Procedures page 102

Hide thumbs Also See for CS 1000E:
Table of Contents

Advertisement

Page 102 of 226
Figure 20
CP PM CP MG Cable
NN43041-464
Standard 05.04
Upgrading Small System hardware
connectors. Use Port 0 for maintenance access, and Port 1 for an external
modem connection.
In a MG 1010, the MGU provides TTY0 and TTY1 serial ports for the Server
card in slot 22 and slot 23. Connect a shielded CAT5 or better Ethernet cable
to a NTC325AAE6 serial port adapter. Attach this cable to the MGU port
labelled TTY0 for CP1 or CP2. CP1 is for slot 22, CP2 is for slot 23.
Avaya recommends you use direct connections from the faceplate jacks of the
Server cards to the Layer 2 ethernet switches. Figure 20 on
illustrates a Media Gatweay chassis with a CP PM Call Processor connected
directly to a Layer 2 switch. Figure 21 on
Gateway chassis with a CP PM Signaling Server connected directly to a
Layer 2 switch.