— Insert the end of a longer RJ-45 CAT5 Ethernet cable (not
supplied) into the TLAN network interface port (TLAN port) on
the faceplate of the Signaling Server
— Insert the other end of the RJ-45 CAT5 Ethernet cable into an
Ethernet port on the TLAN subnet of the Layer 2 switch
Note: When you connect using this method, data packet captures cannot
be captured from the device without disrupting service.
If the Call Server connects directly to the Gateway Controller, you must
obtain shielded CAT5 Ethernet cables that are long enough to connect the
Signaling Server ELAN and TLAN Ethernet ports directly to the ELAN and
TLAN ports of the Layer 2 switches.
4
Configure the COM port on the maintenance terminal as follows:
Terminal type: VT-100
Speed: 9 600
Data bits: 8
Parity: none
Stop bits: 1
Flow control: none
Note: The CP PM card ships with the Admin Serial port configured to
9600 Bit/s. Other available speeds are 19 200, 38 400, and 115 200 Bits.
You can change the port speed by using the maintenance terminal. To
verify or change the baud rate on a CP PM card, see Linux Platform Base
and Applications Installation and Commissioning (NN43001-315).
5
Configure the Signaling Server with the maintenance terminal. See Linux
Platform Base and Applications Installation and Commissioning
(NN43001-315).
Perform the following procedure to cable a CP MG cardas a Signaling Server.
Avaya Communication Server 1000E Upgrade
Installing a Signaling Server
End of Procedure
Hardware Upgrade Procedures
Page 183 of 226