Avaya CS 1000E Upgrade Procedures page 163

Hide thumbs Also See for CS 1000E:
Table of Contents

Advertisement

Upgrading a CP PII or CP PIV to CP PM
faceplate port labelled TTY0 for CP1 or CP2. CP1 is for slot 22, CP2
is for slot 23.
Connect the opposite end of the serial cable to the serial port on the
maintenence terminal.
Note: To connect a terminal to the CP PM card with a NTAK19EC cable,
perform the following steps:
Connect the NTAK19EC cable (shipped with the CP PM Signaling
Server) to the 50 pin MDF connector on the back of the desired
MG 1000E.
Connect a 25 pin to 9 pin straight through serial cable to the 25 pin
DB connector at the end of the NTAK19EC cable (a female to female
gender changer may be required). You must povide this adapter.
Connect the other end of the 25 pin to 9 pin straight through serial
cable to the serial port on the maintenance terminal.
Avaya Communication Server 1000E Upgrade
End of Procedure
Hardware Upgrade Procedures