Installing The Cp Pm Card - Avaya CS 1000E Upgrade Procedures

Hide thumbs Also See for CS 1000E:
Table of Contents

Advertisement

Page 162 of 226

Installing the CP PM card

NN43041-464
Standard 05.04
Upgrading a CP PII or CP PIV to CP PM
The following procedure describes how to install the CP PM card in a Media
Gateway.
MG 1010 slots 22 and 23 require the NTDW99 CP PM card with metal
faceplate. MG 1000E and MG 1010 slots 1-10 support NTDW61 and
NTDW99 CP PM cards.
MG 1010, you can install additional CP PM cards in slots 1-10.
Ensure that the Dip Switch (S5) is set to position 1 if using the CP PM as a
Call Server or position 2 if using the card as a CP PM Signaling Server.
Procedure 23
Installing the CP PM card
1
Ensure that the security dongle (the one that comes as part of the
software kit) is inserted on the CP PM call processor.
Note 1: This first step is applicable only when the CP PM card is used as
a Call Server.
Note 2: Remove the retainer clip from the FMD slot when the card is
used as a Signaling Server. The clip must be removed to prevent it from
shorting out adjacent cards.
2
Ensure that the FMD (1 GB) is correctly inserted and locked in place.
3
Insert the CP PM card.
Slide the CP PM call processor into Slot 1 (or higher)
MG 1000E cabinet or chassis
Slide the CP PM call processor into Slot 22 or 23 of the MG 1010
chassis.
4
Lock the card into the faceplate latches.
5
Connect the serial cable.
On a MG 1000E or MG 1010 with CP PM cards in slots 1-10,connect
the 2-port SDI cable. The 50-pin Amphenol NTAK19EC connects to
the back of the CP PM call server.
For a MG 1010, connect a shielded CAT5 Ethernet cable to the
NTC325AAE6 serial cable kit. Connect this cable to the MGU
December 2011
If you require more than two CP PM cards in a
.
of the