Avaya CS 1000E Upgrade Procedures page 148

Hide thumbs Also See for CS 1000E:
Table of Contents

Advertisement

Page 148 of 226
NN43041-464
Standard 05.04
Upgrading a CP PII or CP PIV to CP PM
Media Gateway 1010
The following rules apply to the placement of the CP PM cards in the Media
Gateway 1010:
When facing the front of the MG 1010, from left to right is MGU slot 21,
Server card slots 22and 23, Gatewy Controller slot 0, a metal divider, and
IPE slots 1 to 10.
The CP PM card cannot be placed in slot 0 of any Media Gateway. Slot
0 is reserved for the Gateway Controller.
The MG 1010 provides dedicated slots 22 and 23 for Server cards
The MG 1010 supports a 12 CP PM configuration. A maximum of ten
additional CP PM cards can be placed in IPE slots 1 through 10. CP PM
cards in slots 1-10 of a MG 1010 require the NTAK19EC for serial
connections.
An MG 1010 with greater than five but less than 12 CP PM cards
requires a blank card assembly kit (NTC350AAE6) for EMC
containment. Five blank cards are included in the blank card assembly
kit.
If utilizing the Campus Redundancy High Availability (HA) Call Server
option, place the two CP PM Call Servers in separate chassis' to allow
for increased survivability. HA is not supported on a Co-resident Call
Server and Signaling Server system.
Figure 35 on
page 149
an MGC in slot 0, a CP PM Call Server, and a CP PM Signaling Server in the
main chassis.
December 2011
shows a SA Media Gateway 1010 chassis system with