M1/Cs 1000 Switch Connectivity; To Configure One Mpb96 Board - Avaya CallPilot 1002rp Maintenance And Diagnostics

Hide thumbs Also See for CallPilot 1002rp:
Table of Contents

Advertisement

Configuring MPB96 boards

M1/CS 1000 switch connectivity

To configure one MPB96 board

Plug the MPB96 card in PCI slot 3.
To configure three MPB96 boards
1. Plug the first MPB96 board in PCI slot 3.
2. Plug the second MPB96 board in PCI slot 6.
3. Plug the third MPB96 in PCI slot 9.
4. Connect the 7-drop CT Bus cable to all MPB96 and T1 boards, with the end
124
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
connectors of the CT Bus cable connected to MPB96 in slot 3 and MPB96 in slot 9.
Note:
There should be no dangling connectors at either end of the CT Bus cable.
December 2010