Hard drive bay
a. RAID pairs (logical drives) consist of the following pairs: hard drives 1 and 4,2 and 5,
and 3 and 6. these pairs are represented in the software with the lables A01-01 and A01-02,
A02-01 and A02-02, and A03-02, A03-02 where the first number is the logical drive number
(for example, A03) and the second number indicates if it is the primary or secondary hard
drive (01 for primary and 02 for secondary)
To replace hot-pluggable SCA SCSI hard drives
1.
2. Open the front bezel doors.
3. Locate the SCA SCSI drive frame below a cooling fan and beside the media drive.
4. Loosen the two thumbscrews on the carrier of the faulty hard drive, and remove the
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
SCSI
channel
Caution:
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
Ensure the new hard drive has the SCSI ID set to 0, termination disabled, and parity
checking enabled.
carrier from the chassis.
SCSI ID
Logical drive label
RAID SCSI hard drive configuration
a
December 2010