18. Reconnect the AC or DC mains power.
19. Reboot the CallPilot server and bring it into full service.
Replacing the cooling fan
The cooling fan is hot-swappable, so you can replace the cooling fan without powering down
the server.
When to hot-swap the cooling fan
When the LED associated with a cooling fan turns red, the fan requires replacement.
Caution:
Risk of equipment damage
Use an ESD wrist strap to protect static-sensitive components.
To hot-swap a cooling fan
1. Remove the front bezel.
2. Use the front panel display LED to locate the defective fan.
3. Loosen the thumbscrew located on the outside of the failed cooling fan module (see
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
A
Figure 17: Cooling fan thumbscrew
If needed, use a flat-blade screwdriver. The thumbscrew must rotate freely and not
contact the chassis threads.
Replacing the cooling fan
on page 88).