Procedure 83
Reconfiguring an ITG-P 24-port card running CS 1000 Release 4.0 (Leader
or Follower)
Step
1
2
Copyright © 2003–2008, Nortel Networks
.
Every node must have a Leader. To set the Leader flag for the ITG-P
24 port card, enter
BIOS>nvramLeaderSet
At the prompt, enter
sysReboot
Use Element Manager to select this Voice Gateway Media Card.
Click Transfer to Selected Elements to transfer the config.ini and
bootp.tab files to the card.
See
The account information is synchronized with the Call Server.
Logon to the card using the current username and password.
At IPL> prompt, enter
cardReset
Use standard procedures to upgrade the Voice Gateway Media Card
8051XA Controller firmware and the software, if necessary.
Procedure 83 "Reconfiguring an ITG-P 24-port card running CS 1000
Action
Press the reset button on the ITG-P 24-port card faceplate.
Access the card by the EIA232 Maintenance port.
Nortel Communication Server 1000
IP Line Fundamentals
NN43100-500 02.02 Standard
Release 5.5 4 February 2008
Reconfiguring the Voice Gateway Media Card 557
Description
ELAN IP Address
ELAN subnet mask
ELAN Gateway IP address
—End—