Replacing The Alarm Board - Avaya CallPilot 1002rp Maintenance And Diagnostics

Hide thumbs Also See for CallPilot 1002rp:
Table of Contents

Advertisement

Replacing basic chassis components
Figure 18: Fuse receptacle
5. Slide the fuse receptacle out of the fuse chamber.
6. Remove the blown fuse from the fuse receptacle.
7. Install the approved replacement fuse. Use a flat-blade screwdriver to screw in the
8. Slide the fuse receptacle back into its chamber.
9. Fasten the fuse receptacle with a flat-blade screwdriver.
10. Plug the power cable back into the power input socket on the server.
11. Plug the power cable into the wall outlet.
12. Power on the server.
Important:
If the fuse blows after replacement, swap one power supply module with the other. If this
does not work, call your Avaya customer support representative.

Replacing the alarm board

The 1002rp server alarm board and status panel are used to monitor and indicate the server
status. The basic hardware check on page
defective or damaged. When these units are damaged, replace them immediately.
90
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
Note:
Observe how the blown fuse is positioned in the receptacle.
fuse receptacle with a push and 1/4 clockwise turn.
Basic hardware check