Installing the server and connecting the peripheral devices

Connecting the server to the ELAN subnet

Connect the CallPilot server to the Meridian 1 switch or CS 1000 system using the Embedded
LAN (ELAN).
Important:
For important considerations about using the ELAN subnet in your network, see the Planning
and Engineering Guide (NN44200-200).
Important:
To comply with EMC requirements, a Class A hub must be located 10 m (33 feet) away from
the 703t server.
To connect the server to the ELAN subnet (Meridian 1 or CS
1000 only)
1. Locate the ELAN Ethernet connector on the back of the server.
2. Connect an RJ-45 network cable from the ELAN hub to the server's ELAN
3. At the switch, connect the ELAN network cable to an MAU (Ethernet) transceiver.
42
Avaya CallPilot® 703t Server Hardware Installation
Note:
The ELAN connector is labeled as NIC1 10/100 MB. For the connector location,
see the diagram on
connector.
Note:
The ELAN hub is optional if you use a cross-over network cable to make a direct
point-to-point connection from the server to the switch. However, if you choose
to establish a direct point-to-point ELAN subnet connection, no other device can
connect to the ELAN subnet.
Then complete the connection from the transceiver to the switch.
Danger:
Risk of fire hazard
The NTRH9069 MAU is not suitable for installation in ducts, plenums, or other
spaces used for environmental air. Do not install it above a false ceiling or below a
Rear panel
on page 39.