To replace or add an MPB96 board
1. Courtesy stop all CallPilot channels.
2. Power down the server and all peripheral devices.
3. Disconnect the following cables:
4. Remove the server cover.
5. Unpack the replacement MPB96 board.
6. Hold the MPB96 board by its top edge or upper corners and then align it with the
7. Press the new MPB96 board firmly into its slot.
8. Secure the board using the retaining screw.
9. Reattach the CTbus cable. Refer to
10. Replace the server cover.
11. Replace the front bezel and lock it.
12. Reconnect the peripheral device and power cables.
13. Reconnect the DS30X cable to the faceplate of the MPB96 board.
14. Power up the server and log on to Windows.Result:The Windows New Hardware
Avaya CallPilot® 1002rp Server Maintenance and Diagnostics
a. power cable
b. peripheral device cables
c. DS30X cables (Meridian 1 and Communication Server 1000 only)
d. CTbus cable (if present)
For instructions on removing the server cover, see
server cover
on page 75.
following:
• end-plate opening in the chassis (ensure that the tapered foot of the board's
retaining bracket fits into the slot in the expansion slot frame)
• PCI connector
Note:
Ensure that a single-point ground reference is available for all the power outlets
serving the CallPilot server and its peripherals. Before the CallPilot server
installation, a qualified electrician must implement the single-point ground
reference requirement between the power outlets of the CallPilot server and the
power outlets of the switch.
Found Wizard screen appears.
Important:
Before clicking Next to install the hardware driver, wait 10 minutes or until you
see the dialog box "CallPilot is running and is able to accept calls"; otherwise the