reMOve DraiN HOSe, BraCkeT aND CuP
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the cabinet front (see page 4-16).
2.
Move the hose clamp that secures the drain
hose to the pump with pliers down the hose
off the pump outlet. (see page 4-48).
3.
Remove the drain hose bracket by pushing
down on the bracket to close the clamp and
pull it out of the hole in the base. This is a
split clamp that spreads when it is inside the
hole.
4.
Press down on the pressure clip at the top
of the drain cup and push the cup through
the hole of the feature panel.
5.
Lift the drain cup slightly and pull the drain
cup and drain hose out from the rear of the
feature panel
Clamp
4-37
Drain cup