Remove Inlet Valve - Maytag MAT14CS Service Manual

Next generation top load commercial washer coin and non-coin
Hide thumbs Also See for MAT14CS:
Table of Contents

Advertisement

Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Remove the 5/16 inch hex head screw that
secures the inlet valve mounting plate to the
rear of the feature panel.

reMOve iNLeT vaLve

5/16 inch
hex screw
4-46
2.
Lift the mounting plate up and tilt away from
the feature panel to remove the mounting
plate, inlet valve, thermistor and gain
access to the inlet tubing connection.
3.
Remove the 1/4 inch screw that secures it
to the mounting plate.
4.
Slide the valve up to remove the valve from
the oblong holes that hold it tightly in the
mounting plate.
Mounting plate
1/4 inch screw

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mat14pdMat14prMat15mn