H4: Analog Outputs - YASKAWA A1000 Series Quick Start Manual

High performance vector control drive
Hide thumbs Also See for A1000 Series:
Table of Contents

Advertisement

B.7 H Parameters: Multi-Function Terminals
H3-oo Setting
Function
Output frequency
9
lower limit level
B
PID feedback
C
PID setpoint
D
Frequency bias
Motor temperature
E
(PTC input)
F
Through mode
10
Forward torque limit
11
Reverse torque limit
Regenerative torque
12
limit
Torque Limit Using
13
Torque Reference/
Speed Control
14
Torque compensation
15
General torque limit
Differential PID
16
feedback
Motor Thermistor
17
(NTC)
1F
Through mode
DriveWorksEZ
30 to 32
analog input 1 to 3
u

H4: Analog Outputs

No.
(Addr.
Name
Hex)
Multi-Function Analog
H4-01
Output Terminal FM
(041D)
Monitor Selection
H4-02
Multi-Function Analog
(041E)
Output Terminal FM
Gain
H4-03
Multi-Function Analog
(041F)
Output Terminal FM
Bias
Multi-Function Analog
H4-04
Output Terminal AM
(0420)
Monitor Selection
H4-05
Multi-Function Analog
(0421)
Output Terminal AM
Gain
H4-06
Multi-Function Analog
(0422)
Output Terminal AM
Bias
296
H3 Multi-Function Analog Input Settings
LCD Display
Description When Output Is 100%
10 V = E1-04 (maximum output frequency)
Ref Lower Limit
PID Feedback1
10 V = 100%
PID Set Point
10 V = 100%
Freq Ref Bias 2
10 V = E1-04 (maximum output frequency)
10 V = 100%
Motor PTC
Select this setting when the terminal is not used or when using the terminal
Not Used
in the pass-through mode.
Fwd Torque Limit
10 V = Motor rated torque
Rev Torque Limit
10 V = Motor rated torque
10 V = Motor rated torque
Regen Torq Limit
10 V = Motor rated torque
Torque Reference
Torque Comp
10 V = Motor rated torque
Torque Limit
10 V = Motor rated torque
10 V = 100%
PID Feedback 2
10 V = -9 °C
0 V = +234 °C
Moter temp (NTC)
Select this setting when the terminal is not used or when using the terminal
Not Used
in the pass-through mode.
Output is determined by the function selected using DWEZ.
LCD Display
Selects the data to be output through multi-function analog
output terminal FM.
Term FM FuncSel
Set the desired monitor parameter to the digits available in
Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal FM that is equal to 100% of the
selected monitor value.
Terminal FM Gain
Sets the signal level at terminal FM that is equal to 0% of the
selected monitor value.
Terminal FM Bias
Selects the data to be output through multi-function analog
output terminal AM.
Terminal AM Sel
Set the desired monitor parameter to the digits available in
Uo-oo.
For example, enter "103" for U1-03.
Sets the signal level at terminal AM that is equal to 100% of
the selected monitor value.
Terminal AM Gain
Sets the signal level at terminal AM that is equal to 0% of the
selected monitor value.
Terminal AM Bias
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
Note:
This setting is only available in models 4A0930 and
4A1200.
Description
Page
Values
Page
Default: 102
Range: 000 to
157
999
Default: 100.0%
Min.: -999.9
158
Max.: 999.9
Default: 0.0%
Min.: -999.9
158
Max.: 999.9
Default: 103
Range: 000 to
157
999
Default: 50.0%
Min.: -999.9
158
Max.: 999.9
Default: 0.0%
Min.: -999.9
158
Max.: 999.9

Hide quick links:

Advertisement

Table of Contents
loading