Parameter - Mitsubishi MR-J4-10A Instruction Manual

Melservo j4 servo amplifier
Table of Contents

Advertisement

7. SPECIAL ADJUSTMENT FUNCTIONS

7.2.3 Parameter

When using the gain switching function, always select "Manual mode (_ _ _ 3)" of "Gain adjustment mode
selection" in [Pr. PA08 Auto tuning mode]. The gain switching function cannot be used in the auto tuning
mode.
(1) Variable gain operation setting parameter
Parameter
Symbol
PB26
CDP
Gain switching selection
PB27
CDL
Gain switching condition
PB28
CDT
Gain switching time constant
(a) [Pr. PB26 Gain switching function]
Used to set the gain switching condition. Select the switching condition in the first digit and second
digit.
(b) [Pr. PB27 Gain switching condition]
Set a level to switch gains after you select "Command frequency", "Droop pulses", or "Servo motor
speed" in [Pr. PB26 Gain switching function].
The setting unit is as follows.
(c) [Pr. PB28 Gain switching time constant]
You can set the primary delay filter to each gain at gain switching. This parameter is used to
suppress shock given to the machine if the gain difference is large at gain switching, for example.
Name
Unit
[kpulse/s]
/[pulse]
/[r/min]
[ms]
[Pr. PB26]
0 0
Gain switching selection
0: Disabled
1: Input device (gain switching (CDP))
2: Command frequency
3: Droop pulses
4: Servo motor speed
Gain switching condition
0: Gain after switching is enabled with gain switching condition or more
1: Gain after switching is enabled with gain switching condition or less
Gain switching condition
Command frequency
Droop pulses
Servo motor speed
7 - 17
Description
Used to select the changing condition.
Used to set the changing condition values.
You can set the filter time constant for a gain change at
changing.
[kpulse/s]
[pulse]
Unit
[r/min]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents