Mitsubishi MR-J4-10A Instruction Manual page 32

Melservo j4 servo amplifier
Table of Contents

Advertisement

1. FUNCTIONS AND CONFIGURATION
Function
Output signal selection
(device settings)
Output signal (DO) forced
output
Restart after instantaneous
power failure
Command pulse selection
Torque limit
Speed limit
Status display
External I/O signal display
Automatic VC offset
Alarm code output
Test operation mode
Analog monitor output
MR Configurator2
Linear servo system
Direct drive
servo system
Fully closed loop system
One-touch tuning
Tough drive function
Drive recorder function
STO function
Servo amplifier life diagnosis
function
Power monitoring function
Machine diagnosis function
The output devices including MBR (Electromagnetic brake interlock) can be assigned
to certain pins of the CN1 connector.
Output signal can be forced on/off independently of the servo status.
Use this function for checking output signal wiring, etc.
If the input power supply voltage had reduced to cause an alarm but has returned to
normal, the servo motor can be restarted by merely switching on the start signal.
(available in the future)
Command pulse train form can be selected from among three different types.
Servo motor torque can be limited to any value.
Servo motor speed can be limited to any value.
Servo status is shown on the 5-digit, 7-segment LED display
On/off statuses of external I/O signals are shown on the display.
Voltage is automatically offset to stop the servo motor if it does not come to a stop
when VC (Analog speed command) or VLA (Analog speed limit is 0 V.
If an alarm has occurred, the corresponding alarm number is outputted in 3-bit code.
Jog operation, positioning operation, motor-less operation, DO forced output, and
program operation
MR Configurator2 is required to perform positioning operation or program operation.
Servo status is output in terms of voltage in real time.
Using a personal computer, you can perform the parameter setting, test operation,
monitoring, and others.
Linear servo system can be configured using a linear servo motor and liner encoder.
This is used with servo amplifiers with software version A5 or later. Check the
software version of the servo amplifier using MR Configurator2.
The direct drive servo system can be configured to drive a direct drive motor.
This is used with servo amplifiers with software version A5 or later. Check the
software version of the servo amplifier using MR Configurator2.
Fully closed loop system can be configured using the load-side encoder.
This is used with servo amplifiers with software version A5 or later. Check the
software version of the servo amplifier using MR Configurator2.
Gain adjustment is performed just by one click on a certain button on MR
Configurator2 or operation section.
This function makes the equipment continue operating even under the condition that
an alarm occurs.
The tough drive function includes two types: the vibration tough drive and the
instantaneous power failure tough drive.
This function continuously monitors the servo status and records the status transition
before and after an alarm for a fixed period of time. You can check the recorded data
on the drive recorder window on MR Configurator2 by clicking the "Graph" button.
However, the drive recorder will not operate on the following conditions.
1. You are using the graph function of MR Configurator2.
2. You are using the machine analyzer function.
3. [Pr. PF21] is set to "-1".
This function is a functional safety that complies with IEC/EN 61800-5-2. You can
create a safety system for the equipment easily.
You can check the cumulative energization time and the number of on/off times of the
inrush relay. This function gives an indication of the replacement time for parts of the
servo amplifier including a capacitor and a relay before they malfunction.
MR Configurator2 is necessary for this function.
This function calculates the power running energy and the regenerative power from
the data in the servo amplifier such as speed and current. Power consumption and
others are displayed on MR Configurator2.
From the data in the servo amplifier, this function estimates the friction and vibrational
component of the drive system in the equipment and recognizes an error in the
machine parts, including a ball screw and bearing.
MR Configurator2 is necessary for this function.
Description
1 - 15
Detailed
explanation
[Pr. PD23] to
[Pr. PD28]
Section 4.5.8
[Pr. PA13]
Section 3.6.1
(5)
[Pr. PA11]
[Pr. PA12]
Section 3.6.3
(3)
[Pr. PC05] to
[Pr. PC11]
Section 4.5
Section 4.5.7
Section 4.5.4
Chapter 8
Section 4.5.9
[Pr. PC14],
[Pr. PC15]
Section 11.7
Chapter 15
Chapter 16
Chapter 17
Section 6.1
Section 7.3
[Pr. PA23]
Chapter 13

Hide quick links: