12. ABSOLUTE POSITION DETECTION SYSTEM
(2) Transmission error
(a) [AL. E5 ABS time-out warning]
In the ABS transfer mode, the servo amplifier processes time-out below, and displays [AL. E5] when
a time-out error occurs.
[AL. E5 ABS time-out warning] is cleared when ABSM changes from off to on.
1) ABS request off-time time-out check (applied to 32-bit absolute position data in 2-bit units
checksum)
If the ABS request signal is not turned on by the programmable controller within 5 s after ABST is
turned on, this is regarded as a transmission error and [AL. E5 ABS time-out warning] is output.
ABSM
ABSR
ABST
[AL. E5]
2) ABS request on-time time-out check (applied to 32-bit absolute position data in 2-bit units
checksum)
If the ABSR is not turned off by the programmable controller within 5 s after ABST is turned off,
this is regarded as the transmission error and [AL. E5 ABS time-out warning] is output.
ABSM
ABSR
ABST
[AL. E5]
ON
OFF
ON
OFF
ON
OFF
Yes
No
ON
OFF
ON
OFF
ON
OFF
Yes
No
12 - 20
5 s
Signal is not turned ON
5 s
Signal is not turned OFF