5. PARAMETERS
5.1.1 Basic setting parameters ([Pr. PA_ _ ])
No.
Symbol
PA01
*STY
Operation mode
PA02
*REG
Regenerative option
PA03
*ABS
Absolute position detection system
PA04
*AOP1
Function selection A-1
PA05
*FBP
Number of command input pulses per revolution
PA06
CMX
Electronic gear numerator (command pulse multiplication
numerator)
PA07
CDV
Electronic gear denominator (command pulse multiplication
denominator)
PA08
ATU
Auto tuning mode
PA09
RSP
Auto tuning response
PA10
INP
In-position range
PA11
TLP
Forward rotation torque limit/positive direction thrust limit
PA12
TLN
Reverse rotation torque limit/negative direction thrust limit
PA13
*PLSS
Command pulse input form
PA14
*POL
Rotation direction selection/travel direction selection
PA15
*ENR
Encoder output pulses
PA16
*ENR2
Encoder output pulses 2
PA17
*MSR
Servo motor series setting
PA18
*MTY
Servo motor type setting
PA19
*BLK
Parameter writing inhibit
PA20
*TDS
Tough drive setting
PA21
*AOP3
Function selection A-3
PA22
For manufacturer setting
PA23
DRAT
Drive recorder arbitrary alarm trigger setting
PA24
AOP4
Function selection A-4
PA25
OTHOV
One-touch tuning - Overshoot permissible level
PA26
*AOP5
Function selection A-5
PA27
For manufacturer setting
PA28
PA29
PA30
PA31
PA32
Name
5 - 2
Operation
Initial
Unit
value
1000h
0000h
0000h
2000h
10000
1
1
0001h
16
100
[pulse]
100.0
[%]
100.0
[%]
0100h
0
4000
[pulse/rev]
1
0000h
0000h
00AAh
0000h
0001h
0000h
0000h
0000h
0
[%]
0000h
0000h
0000h
0000h
0000h
0000h
0000h
Control
mode
mode

Hide quick links: