Magnetic Pole Detection - Mitsubishi MR-J4-10A Instruction Manual

Melservo j4 servo amplifier
Table of Contents

Advertisement

16. USING A DIRECT DRIVE MOTOR
(2) Operation at the magnetic pole detection
WARNING
CAUTION
(a) Incremental system
By turning on SON (Servo-on) after power-on, the magnetic pole detection is automatically carried
out. Therefore, there is not need to set the parameter (first digit of [Pr. PL01]) for executing the

magnetic pole detection.

1) Timing chart
Note that the magnetic pole detection automatically starts simultaneously with the
turning-on of the servo-on command.
If the magnetic pole detection is not executed properly, the direct drive motor may
operates unexpectedly.
POINT
Establish the machine configuration to use LSP (Forward rotation stroke end)
and LSN (Reverse rotation stroke end). The machine may be damaged due to a
collision without LSP and LSN.
Assign LSP and LSN and perform the magnetic pole detection also in the torque
control mode.
At the magnetic pole detection, whether the motor rotates in the forward or
reverse direction is unpredictable.
Depending on the setting value of [Pr. PL09 Magnetic pole detection voltage
level], an overload, overcurrent, magnetic pole detection alarm, or others may
occur.
After the magnetic pole detection, check the positioning accuracy with the test
operation (positioning operation function) of MR Configurator2.
The accuracy of the magnetic pole detection improves with no load.
POINT
For the incremental system, the magnetic pole detection is required every time
the power is turned on.
SON (Servo-on)
Base circuit
RD (Ready)
Note. The magnetic pole detection time indicates the operation time when LSP (Forward
rotation stroke end) and LSN (Reverse rotation stroke end) are on.
ON
OFF
95 ms
ON
OFF
ON
OFF
15 s or less
Magnetic pole detection time (Note)
16 - 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents