15. USING A LINEAR SERVO MOTOR
(2) When using serial linear encoder with MR-J4-_A_-RJ
The following configuration diagram shows an example for using a linear servo motor with MR-J4-10A-
RJ.
R S T
(Note 2)
Power supply
Molded-case
circuit breaker
(MCCB)
(Note 3)
Magnetic
contactor
(MC)
(Note1)
Line noise
filter
(FR-BSF01)
L1
L2
L3
Power factor
P3
improving
DC reactor
(FR-HEL)
P4
P+
Regenerative
option
C
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P3 and P4.
2. A 1-phase 200 V AC to 240 V AC power supply may be used with the servo amplifier of MR-J4-70A or less. For 1-phase 200 V
AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For the power supply specifications, refer to section
1.3.
3. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
4. For the branch cable, use the MR-J4THCBL03M (optional).
5. Always connect between P+ and D terminals. When using the regenerative option, refer to section 11.2.
6. Connect the thermistor to THM of branch cable and connect the encoder cable to SCALE correctly. Incorrect setting will trigger
[AL. 16].
D
(Note 5)
U
V
W
L11
L21
MR Configurator2
CN5
CN6
CN3
Personal computer and others
CN8
CN1
CN2
15 - 3
Personal
computer
Analog monitor
To safety relay or
MR-J3-D05 safety logic unit
Junction terminal block
(Note 6)
SCALE
THM
(Note 4)
Thermistor
Linear servo motor
Serial linear encoder
Encoder
cable