10. CHARACTERISTICS
Servo amplifier
Servo motor
HG-JR903
MR-J4-11KA(-RJ)
HG-JR11K1M
MR-J4-15KA(-RJ)
HG-JR15K1M
MR-J4-22KA(-RJ)
HG-JR22K1M
HG-SR524
MR-J4-60A4(-RJ)
HG-JR534
HG-SR1024
MR-J4-100A4(-RJ)
HG-JR734
HG-JR1034
HG-SR1524
HG-SR2024
MR-J4-200A4(-RJ)
HG-JR1534
HG-JR2034
HG-SR3524
MR-J4-350A4(-RJ)
HG-JR3534
HG-SR5024
MR-J4-500A4(-RJ)
HG-JR5034
HG-SR7024
MR-J4-700A4(-RJ)
HG-JR7034
HG-JR9034
MR-J4-11KA4(-RJ)
HG-JR11K1M4
MR-J4-15KA4(-RJ)
HG-JR15K1M4
MR-J4-22KA4(-RJ)
HG-JR22K1M4
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value is applicable when the
power factor improving AC reactor or power factor improving DC reactor are not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat generated by the
regenerative option, refer to section 11.2.
3. This value is applicable when the servo amplifier is cooled by using the heat sink outside mounting attachment.
(Note 2) Servo amplifier-generated heat [W]
(Note 1)
Power supply
capacity
At rated output
[kVA]
13
435
16
530
22
640
33
850
1.0
40
1.0
40
1.7
60
1.3
60
1.7
60
2.5
90
3.5
90
2.5
90
3.5
90
5.5
130
5.5
160
7.5
195
7.5
195
10
300
10
300
13
435
16
530
22
640
33
850
10 - 5
At rated output
[Generated heat
in the cabinet
With servo-off
when cooled
outside the
cabinet] (Note 3)
130
45
160
45
195
45
260
55
18
18
18
18
18
20
20
20
20
20
20
25
25
25
25
130
45
160
45
195
45
260
55
Area required for
heat dissipation
2
[m
]
8.7
11.0
13.0
17.0
0.8
0.8
1.2
1.2
1.2
1.8
1.8
1.8
1.8
2.6
2.7
3.9
3.9
6.0
6.0
8.7
11.0
13.0
17.0

Hide quick links: