11. OPTIONS AND AUXILIARY EQUIPMENT
Power factor
Servo amplifier
improving DC
reactor
MR-J4-60A4(-RJ)
FR-HEL-H1.5K
MR-J4-100A4(-RJ)
FR-HEL-H2.2K
MR-J4-200A4(-RJ)
FR-HEL-H3.7K
MR-J4-350A4(-RJ)
FR-HEL-H7.5K
MR-J4-500A4(-RJ)
FR-HEL-H11K
MR-J4-700A4(-RJ)
FR-HEL-H15K
MR-J4-11KA4(-RJ)
MR-J4-15KA4(-RJ)
FR-HEL-H22K
MR-J4-22KA4(-RJ)
FR-HEL-H30K
Note. Selection conditions of wire size is as follows.
Wire type: 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
Dimensions [mm]
Dimensions
W
W1
H
66
50
100
Fig. 11.4
76
50
110
86
55
120
Fig. 11.5
96
60
128 105
105
75
137 110
105
75
152 125
Fig. 11.6
133
90
178 120
133
90
178 120
11 - 65
D
D1
D2
D3
d
80
74
54
37
M4
80
74
54
37
M4
95
89
69
45
M4
100
80
50
M5
105
85
53
M5
115
95
62
M5
95
75
53
M5
100
80
56
M5
Terminal
Mass
Wire [mm
size
[kg]
(Note)
M3.5
1.0
2 (AWG 14)
M3.5
1.3
2 (AWG 14)
M4
2.3
2 (AWG 14)
M4
3.5
2 (AWG 14)
M5
4.5
3.5 (AWG 12)
5.5 (AWG 10)
M6
5.0
8 (AWG 8)
M6
6.0
8 (AWG 8)
M6
6.5
14 (AWG 6)
2
]