Mitsubishi MR-J4-10A Instruction Manual page 358

Melservo j4 servo amplifier
Table of Contents

Advertisement

11. OPTIONS AND AUXILIARY EQUIPMENT
Note 1. For power supply specifications, refer to section 1.3.
2. For the servo amplifier of 7 kW, always disconnect the lead wire of built-in regenerative resistor, which is connected to the P+
and C terminals. For the servo amplifier of 11 kW to 22 kW, do not connect a supplied regenerative resistor to the P+ and C
terminals.
3. Between P3 and P4 is connected by default. When using the power factor improving DC reactor, remove the short bar
between P3 and P4. Refer to section 11.11 for details. Additionally, a power factor improving DC reactor and power factor
improving AC reactor cannot be used simultaneously.
4. Connect P/+ and N/- terminals of the brake unit to a correct destination. Incorrect connection destination results in servo
amplifier and brake unit malfunction.
5. Contact rating: 1b contact, 110 V AC_5 A/220 V AC_3 A
Normal condition: TH1-TH2 is conducting. Abnormal condition: TH1-TH2 is not conducting.
6. Contact rating: 230 V AC_0.3 A/30 V DC_0.3 A
Normal condition: B-C is conducting/A-C is not conducting. Abnormal condition: B-C is not conducting/A-C is conducting.
7. Do not connect more than one cable to each P+ to N- terminals of the servo amplifier.
8. Always connect BUE and SD terminals. (factory-wired)
9. Connect MSG and SD terminals of the brake unit to a correct destination. Incorrect connection destination results in servo
amplifier and brake unit malfunction.
10. For the cable to connect the terminal block and the P+ and N- terminals of the servo amplifier, use the cable indicated in (3)(b)
of this section.
11. Depending on the main circuit voltage and operation pattern, bus voltage decreases, and that may cause the forced stop
deceleration to shift to the dynamic brake deceleration. When dynamic brake deceleration is not required, slow the time to turn
off the magnetic contactor.
12. Configure up a circuit to turn off EM2 when the main circuit power is turned off to prevent an unexpected restart of the servo
amplifier.
13. When wires used for L11 and L21 are thinner than wires used for L1, L2, and L3, use a molded-case circuit breaker.
14. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they
can be configured by one.
(2) Combination with MT-BR5-(H) resistor unit
(a) 200 V class
MCCB
(Note 1)
Power
supply
(Note 10)
Main circuit
power supply
24 V DC
(Note 12)
ALM
RA1
Emergency stop switch
Servo amplifier
(Note 9)
CN1
MC
L1
L2
L3
L11
L21
(Note 11)
CN1
EM2
42
SON
15
20
DICOM
(Note 7)
21
DICOM
OFF
ON
MC
MC
SK
24 V DC (Note 12)
46
DOCOM
47
DOCOM
48
ALM
RA1
P3
(Note 3)
P4
P+
N-
C
(Note 2)
11 - 27
RA2
MT-BR5
SK
(Note 5)
TH1
P
RA2
TH2
PR
FR-BU2
PR
MSG
P/+
SD
(Note 4)
A
N/-
B
C
BUE
(Note 8)
(Note 6)
SD

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents