11. OPTIONS AND AUXILIARY EQUIPMENT

11.4 FR-RC-(H) power regeneration converter

When using the FR-RC-(H) power regeneration converter, set [Pr. PA02] to "_ _ 0 1" and set [Pr. PC27] to "_
_ _ 1".
(1) Selection example
The converters can continuously return 75% of the nominal regenerative power. They are applied to the
servo amplifiers of the 5 kW to 22 kW.
Power regeneration
converter
FR-RC-15K
FR-RC-30K
FR-RC-55K
FR-RC-H15K
FR-RC-H30K
FR-RC-H55K
POINT
When using the FR-RC-(H), power regeneration converter, set [Pr. PA04] to "0 0
_ _" to enable EM1 (Forced stop 1).
When using the FR-RC-(H) power regeneration converter, refer to "Power
Regeneration Converter FR-RC Instruction Manual (IB(NA)66330)".
Nominal
regenerative
Servo amplifier
power
[kW]
MR-J4-500A(-RJ)
15
MR-J4-700A(-RJ)
MR-J4-11KA(-RJ)
30
MR-J4-15KA(-RJ)
55
MR-J4-22A(-RJ)
MR-J4-500A4(-RJ)
15
MR-J4-700A4(-RJ)
MR-J4-11KA4(-RJ)
30
MR-J4-15KA4(-RJ)
55
MR-J4-22KA4(-RJ)
500
300
200
100
50
30
20
11 - 35
0
50
75
100
Nominal regenerative power [%]