Status Display Mode - Mitsubishi MR-J4-10A Instruction Manual

Melservo j4 servo amplifier
Table of Contents

Advertisement

14. COMMUNICATION FUNCTION

14.5.2 Status display mode

(1) Reading the status display name and unit
Read the status display name and unit.
(a) Transmission
Transmit the command [0] [1] and the data No. corresponding to the status display item to be read,
[0] [0] to [0] [E] and [2] [0] to [2] [9]. (Refer to section 14.4.1.)
(b) Return
The slave station returns the status display name and unit requested.
(2) Status display data reading
Read the status display data and processing information.
(a) Transmission
Transmit the command [0] [1] and the data No. corresponding to the status display item to be read,
[8] [0] to [8] [E] and [A] [0] to [A] [9]. (Refer to section 14.4.1.)
(b) Return
The slave station returns the status display data requested.
(3) Status display data clear
The cumulative feedback pulse data of the status display is cleared. Send this command immediately
after reading the status display item. The data of the status display item transmitted is cleared to "0".
For example, after sending command [0] [1] and data No. [8] [0] and receiving the status display data,
send command [8] [1], data No. [0] [0] and data [1EA5] to clear the cumulative feedback pulse value to
"0".
0 0
Unit characters (5 digits)
0 0
Data 32-bit length (hexadecimal representation)
(Data conversion is required as indicated in the display type.)
Display type
0: Data must be converted into decimal.
1: Data is used unchanged in hexadecimal.
Decimal point position
0: No decimal point
1: First least significant digit (normally not used)
2: Second least significant digit
3: Third least significant digit
4: Forth least significant digit
5: Fifth least significant digit
6: Sixth least significant digit
Command
Data No.
[8] [1]
[0] [0]
14 - 20
Name characters (9 digits)
Data
1EA5