3.3.10 EDID

@SED
Command format
Return value
format
Parameter
Example
Related info.
@GED
Command format
Return value
format
Parameter
Example
Related info.
Set EDID
@SED, ch_1, edid_1 (, ch_2, edid_2
@SED, ch_1, edid_1 (, ch_2, edid_2
ch_1-8 : Input channel
0 = All inputs, 1 = IN1 to 5 = IN5
edid_1-5 : EDID data
0 = Built-in EDID [Default],
1 to 4 = EDID loaded from display device connected to OUTA*
5 to 8 = EDID loaded from display device connected to OUTB
101 to 108 = COPY DATA 1 to COPY DATA 8
*1
OUT1B to OUT4B can be set only if Cat5e/Cat6 output option is installed.
*2
EDID data have to be loaded beforehand in @RME Copy EDID (P. 76).
Send
@SED,2,3
Receive
@SED,2,3
8.9.1 EDID setting
Get EDID
@GED
@GED, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8
in_1, in_2, in_3, in_4, in_5 : EDID data of each input channel
0 = Built-in EDID [Default],
1 to 4 = EDID loaded from display device connected to HDMI output
connector
5 to 8 = EDID loaded from display device connected to OUTB*
101 to 108 = COPY DATA 1 to COPY DATA 8
*
OUT1B to OUT4B can be set only if Cat5e/Cat6 output option is installed.
Send
@GED
Receive
@GED,0,0,0,3,0,0,
0,0
8.9.1 EDID setting
MSD-804FD Users Guide (Command Guide)
・・・
)
・・・
)
*2
Set the EDID loaded from the display device that is
connected to OUT3A for IN2.
Terminated normally.
*2
Get EDID data.
IN4: EDID loaded from display device
connected to OUT3; other inputs: built-in
EDID