3.3 Settings

For "Related info." mentioned in each table below, refer to the Users Guide of MSD-804FD.

3.3.1 Error status

@ERR
Error status
Command
Only Return value
format
@ERR, error
Return value
format
Parameter
error : Error status
1 = Erroneous parameter format or value
2 = Undefined command or wrong format
3 = Currently unavailable command
5 = The command could not be executed since no command was registered or the
command was not registered.
6 = The command could not process the command since another command was
being executed.
7 = Automatic measurement of input timing failed.
8 = Loading EDID from the display device failed.
10 = The control command was stopped according to the stop condition.
11 = The control command was stopped since the number of retries exceeded the
12 = The control command of PJLink was stopped since the password did not match.
13 = The image could not be captured since the image size to be captured exceeded
14 = Capturing input image failed.
15 = Could not be set or collected since Cat5e/Cat6 output option is not installed.
Example
Send
Receive
Send
Receive
Send
Receive
set value of "RETRY".
the reserved memory size.
@SSW,999,1
@ERR,1
@XYZ
@ERR,2
@RPM,3
@ERR,3
MSD-804FD Users Guide (Command Guide)
Parameter error
Not defined command
Specified memory number had no data registration