MSD-62 series Command Guide

3.3.11 EDID

@GED / @SED
Getting
Command
Response
Setting
Command
Response
Parameter
Getting
Command
example
Response
Description Getting the set EDID.
Setting
Command
example
Response
Description Setting IN2: EDID that is read from the sink device connected to OUT3.
Remarks
70
EDID
@GED
@GED, edid_1, edid_2, edid_3, edid_4, ・・・, edid_8
@SED, ch_1, edid_1 (, ch_2, edid_2・・・)
@SED, ch_1, edid_1 (, ch_2, edid_2・・・)
edid_1-8: EDID
0 = Built-in EDID [Default],
1 = OUT1 MONITOR,
2 = OUT2 MONITOR,
3 = OUT3 MONITOR,
4 = OUT4 MONITOR,
5 = OUT5 MONITOR,
6 = OUT6 MONITOR,
7 = OUT7 MONITOR,
8 = OUT8 MONITOR,
101 to 108 = COPY DATA 1 to COPY DATA 8
ch_1-8: Input channel
0 = All digital inputs, 1 = IN1 to 8 = IN8
@GED
@GED,0,0,0,3,0,0,0,0
IN4: EDID of the sink device that is connected to OUT3,
other inputs: built-in EDID
@SED,2,3
@SED,2,3
These commands are only for digital input.
IN7 and IN8: If "0" (Analog signal) is selected for "@GIN / @SIN Signal selection
of DVI input connector", "-1" is acquired and the setting cannot be valid.
In order to use a copied data, read EDID data from the sink device in "@RME
Copying EDID" in advance.