@SST
Set saturation
Command
@SST, ch_1, saturation_1 (, ch_2, saturation_2
format
Return value
@SST, ch_1, saturation_1 (, ch_2, saturation_2
format
Parameter
ch_1-9 : Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
saturation_1-9 : Input saturation
0 to 200 [Default]: 100
Example
Send
Receive
Related info.
8.4.4 Saturation
@GST
Get saturation
Command
@GST
format
Return value
@GST, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8, in_9
format
Parameter
in_1-9 : Input saturation of each input channel
0 to 200 [Default]: 100
Example
Send
Receive
Related info.
8.4.4 Saturation
@SSU
Set black level
Command
@SSU, ch_1, setup_1 (, ch_2, setup_2
format
Return value
@SSU, ch_1, setup_1 (, ch_2, setup_2
format
Parameter
ch_1-9 : Input channel
0 = All inputs, 1 = IN1 to 9 = IN9
setup_1-9 : Input setup level
-20 = -20×0.5 (-10.0 %) to +20 = +20×0.5 (+10.0 %) [Default]: ±0 = ±0.0%
Example
Send
Receive
Related info.
8.4.5 Black level
@SST,5,105
@SST,5,105
@GST
@GST,100,100,100,100,105,100,
100,100,100
@SSU,5,15
@SSU,5,15
41
MSD-804FD Users Guide (Command Guide)
・・・
)
・・・
)
Set input saturation of IN5 to 105%.
Terminated normally.
Get input saturation.
IN5: 105% and other inputs: 100%.
・・・
)
・・・
)
Set input setup level of IN5 to +7.5%.
Terminated normally.