IDK MSD-804FD Series Command Manual page 98

Presentation switcher
Hide thumbs Also See for MSD-804FD Series:
Table of Contents

Advertisement

@GEC
Get control command (Control CEC)
Command
@GEC, no
format
Return value
@GEC, no, delay, port, memo, error, ch_1, cec_1 (, ch_2, cec_2
format
Parameter
no : Command number
1 to 32
delay : Delay time
0 to 999999
port : CEC control
524288 = CEC control
memo:
Up to 14 characters of 20 to 7D except 2C (,). "2 ASCII codes"
error : Processing if no reply from destination device
0 = Stop, 1 = Execute (Continue)
ch_1-8 : Output
1 = OUT1A, 2 = OUT2A, 3 = OUT3A, 4 = OUT4A, 5 = OUT1B, 6 =
OUT2B, 7 = OUT3B, 8 = OUT4B*
* Values can be got only if Cat5e/Cat6 output option is installed.
cec_1-4 : Control command
0 =Not controll, 1 = POWER OFF, 2 = POWER ON
Only output settings to be controlled are sent.
Example
Send
Receive
Related info.
8.12.1 Control commands
@GEC,7
@GEC,7,0,524288,DISPLAY1
ON,0,1,2
98
MSD-804FD Users Guide (Command Guide)
・・・
Get control command 7.
・Delay: 0 ms
・Memo: DISPLAY1 ON
・Error: Stop
・Devices connected to OUT1 is ON.
・All other outputs are not controlled.
)