IDK MSD-804FD Series Command Manual page 38

Presentation switcher
Hide thumbs Also See for MSD-804FD Series:
Table of Contents

Advertisement

@GTP
Get test pattern
Command
@GTP
format
Return value
@GTP, p_out_1, s_out_1 (, p_out_2, s_out_2, p_out_3, s_out_3, p_out_4, s_out_4)
format
Parameter
p_out_1-4 : Test pattern of each output
s_out_1-4 : Scrolling
0 = OFF [Default], 1 = 3 pixel/frame to 10 = 30 pixel/frame
Scrolling the output test pattern takes [the set value × 3 = the number of pixels to
be scrolled per frame].
Example
Send
Receive
Related info.
8.3.15 Test pattern
0 = OFF [Default],
1 = VERTICAL COLOR BAR, 2 = HORIZONTAL COLOR BAR,
3 = VERTICAL GRAY SCALE, 4 = HORIZONTAL GRAY SCALE,
5 = VERTICAL LAMP, 6 = HORIZONTAL LAMP,
7 = 100% WHITE RASTER, 8 = 50% WHITE RASTER,
9 = 100% RED RASTER, 10 = 100% GREEN RASTER,]
11 = 100% BLUE RASTER, 12 = CROSS HATCH,
13 = OUTPUT FRAME, 14 = VERTICAL STRIPE,
15 = HORIZONTAL STRIPE, 16 = VERTICAL ZEBRA,
17 = HORIZONTAL ZEBRA
@GTP
@GTP,3,1,0,0,0,0,0,0
38
MSD-804FD Users Guide (Command Guide)
Get output settings of test pattern
OUT1 scrolls "VERTICAL GRAY SCALE" (3
pixels per frame); other outputs do not output
any test pattern.

Advertisement

Table of Contents
loading

Table of Contents