Input Timing - IDK MSD-804FD Series Command Manual

Presentation switcher
Hide thumbs Also See for MSD-804FD Series:
Table of Contents

Advertisement

3.3.7 Input timing

@GHT
Get the total number of horizontal dots
@GHT
Command
format
Return value
@GHT, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8
format
Parameter
in_1-8 : The total number of horizontal dots of each input channel
Example
Send
Receive
Related info.
8.6.1 The total number of horizontal dots
@SHS
Set horizontal start position
@SHS, ch, h_start
Command
format
Return value
@SHS, ch, h_start
format
Parameter
ch : Input channel
h_start : Start position of horizontal fetch
Example
Send
Receive
Send
Receive
Related info.
8.6.2 Horizontal start position
Note
This command is valid only if signals are input.
@GHS
Get horizontal start position
@GHS
Command
format
@GHS, in_1, in_2, in_3, in_4, in_5, in_6, in_7, in_8
Return value
format
Parameter
in_1-8 : Starting position of horizontal shift of each input channel
Example
Send
Receive
Related info.
8.6.2 Horizontal start position
400 to 4125 (Sampling clock: 13 MHz to 162 MHz)
[Default]: Differs depending on input signals
@GHT
@GHT,2200,2200,0,2640,
1344,1792,0,1792,0
0 = All inputs, 1 = IN1 to 8 = IN8
64 to 2900 ([The total number of horizontal dots - Horizontal display period] or
less)
[Default]: Differs depending on input signals
@SHS,5,296
@SHS,5,296
@SHS,6,296
@ERR,3
64 to 2900 ([The total number of horizontal dots - Horizontal display period] or
less)
[Default]: Differs depending on input signals
@GHS
@GHS,192,192,496,0,296,
0,378,378,0
MSD-804FD Users Guide (Command Guide)
Get the total number of horizontal dots.
0 is replied to channels without input
signals.
Set horizontal starting position of IN5 to 296.
Terminated normally.
If no signal is input, an error is replied.
Get horizontal starting position.
0 is replied to channels without input
signals.
47

Advertisement

Table of Contents
loading

Table of Contents