the LiteLOC™ setting, the recovery will be immediate. When re-enabling LiteLOC™ from a brightness setting
that differs by only 10% or less, the recovery will be gradual.
Understanding Lamp Power Values (%)
The Lamp Power % region accepts values from 50-110, which represents the power appropriate for the
installed lamp. In other words, you can apply anywhere from 50% of the maximum power intended for the
installed lamp up to an over-drive that exceeds the maximum rating by approximately 10%. Both current
(amps) and power (watts) thresholds are read.
Keep in mind that higher lamp power settings do shorten lamp life-for best results, avoid over-driving a lamp
for extended periods. When using LiteLOC™ (which automatically increases lamp power over time), check
the Status menu lamp power readings periodically as the lamp ages, to prevent prolonged over-driving.

3.6.2 Using the Lamp Change Wizard

NOTICE: Ensure the lamp is powered OFF before running the Lamp Change Wizard to prevent a hot restrike.
1. For instructions on how to manually change the lamp, refer to the lamp replacement instructions in the
CP2210 Service Manual (P/N: 020-100556-xx).
2. To access the Lamp Change Wizard ensure you are logged in at the service level. For details, refer to
3.4 User Access and Rights, on page
3. Navigate to the Advanced Setup>Lamp Change Wizard window (Figure 3-61).
4. Click Next to access the Add Lamp window (Figure 3-62).
CP2220 User Manual
020-100420-06 Rev. 1 (03-2011)
3-8.
Figure 3-61 Lamp Change Wizard
Section 3: Operation