Christie Solaria CP2220 User Manual page 202

Hide thumbs Also See for Solaria CP2220:
Table of Contents

Advertisement

Appendix B: Serial API
EXAMPLES:
(TMD+DSTA?) 0 or 1 (DST OFF or DST ON)
(TMD+DSTA 0) Turn daylight savigns OFF (0) or ON (1)
(TMD+ZONE 20) Set time zone to EST
(TMD+TIME? ) Get local time (TMD+TIME! 17:50:45)
(TMD+TOFF 120) Increase the time by two minutes.
("TMD+TOFF: Disabled Control") Error message returned when power is OFF.
("TMD+TOFF: LD Real Time Clock Offset range for time adjustment has been exceeded.")
3D Output Reference Polarity (TOP)
Setup output timing signal reference polarity for 3D control.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace xxx with the channel number. Valid range is 101-164.
NONE
Select output reference polarity for the current channel.
EXAMPLES:
(TOP+C101 1) Set Output Reference Polarity to 1 on channel 101
(TOP+C101?) Get Output Reference Polarity on channel 101
User ID (UID)
Allows users to login to the serial interface.
SUBCODE
DESCRIPTION OF USE
NONE
None
EXAMPLES:
(UID) "username" "password") Login a user
(UID) Logout the current user, also happens automatically when a new user logs in
(UID?)(UID! "username" 01) Display the current logged in user and their access level
Zoom Lens Position Adjustment (ZOM)
Adjust lens to specific zoom position with a specified direction (1, -1). NOTE: This command can only be used to
update the current ILS file. Changing the zoom for the current channel will change the zoom for any channel using
the same ILS file.
Use command without subcode:
If ILS is ON, motor will move to specified steps and save data to the active channel.
If ILS is OFF, motor will move to specified steps, do not save data to the active channel.
SUBCODE
DESCRIPTION OF USE
BACN
Motor backlash in negative direction. Read-only.
BACP
Motor backlash in positive direction. Read-only.
CALB
Calibrate travel range and backlash on specified. Only valid parameter for this command is 1. Set only
command.
Cxxx
Replace xxx with the channel number. Valid range is 101-164.
NONE
Moving lens mount to a specified vertical position.
RNGN
Motor moving range in negative direction. Read-only.
RNGP
Motor moving range in positive direction. Read-only.
RSET
Move motor to the center flag then move back to current position. Only valid parameter for this command
is 1. Set only command.
B-24
CP2220 User Manual
020-100420-06 Rev. 1 (03-2011)