Advanced Setup: LampLOC™ Setup Window
LampLOC™ buttons activate motors that reposition the bulb in the projector for optimized light output. Click
the Do Auto button (recommended) to perform LampLOC™ or the individual buttons. NOTES: 1) The lamp
must be ON before beginning LampLOC™. If it is turned off during a re-positioning, the bulb will return to its
former position. 2) The douser opens and remains non-functional during a LampLOC™ adjustment. 3) For
optimized performance during long term operation of the lamp, it may be beneficial to run LampLOC™ every
month or two to improve lamp performance during lamp electrode burn back.
Figure 3-23 Advanced Setup: LampLOC™ Setup Window
Table 3.20 Advanced Setup: LampLOC™ Setup Window
Region
1: Lamp
Position
2: Intensity
CP2220 User Manual
020-100420-06 Rev. 1 (03-2011)
1
3
Control
Description
Left/Right
Manually moves lamp position in the X axis (left/ right for horizontal movement),
Y axis (up/down for vertical movement), and Z axis (in/out for lamp axial axis
Up/Down
movement). The current position of the lamp displays in cartesian coordinates. A
In/Out
single click corresponds to a single integer increment/decrement. Adjust one short
Arrow
click at a time, several longer clicks, or hold the button for an accelerated move-
Buttons
ment. There are projector hardware specific limits, beyond which the lamp posi-
tion will no longer move. These limits are to be defined during implementation.
Value
Shows the current light sensor reading in arbitrary units-of -measure and does not
represent actual lumens or fL. This read-only value is updated automatically from
the projector.
Light Bar
This visual representation of the projector's light sensor indicates the current light
intensity (vertical bar) and LiteLOC™ target (red horizontal line). The
LiteLOC™ target updates automatically by moving the bar up or down based on
the amount of light measured by the projector light sensor. The limits are self
adjusting, so the absolute scale is not important.
Section 3: Operation
2
LiteLOC™
Target
Light
Intensity
3-33