Configuring the Projector for Uninterrupted Power Supply (Optional)
Located in the power compartment of the projector is an IEC 320 outlet where a UPS can be connected. This
allows the projection head electronics to remain operable during a power failure reducing the recovery period
of the projector. Once power returns, all that is required is for the operator to turn the lamp on using the TPC.
1. To configure the projector for UPS, simply unplug the LVPS input connection from Main Power and
connect it to the loose UPS input plug. Re-use the dummy plug from the UPS connection with the unused
Main Power plug. Figure 2-14
CP2220 User Manual
020-100420-06 Rev. 1 (03-2011)
Figure 2-14
Section 2: Installation and Setup
2-11