Section 2: Installation and Setup
STEP 8 - Connect Power
CP2220 is designed as a permanently wired connection or pluggable type B connection. Connecting the
projector to your AC supply can vary according to the country or state in which the projector is installed. For
any installation, always follow the electrical code for your location.
WARNING
safety. Never compromise safety by returning the current through the ground. 3) Connect
ground FIRST to reduce shock hazard from high leakage.
the cable from rubbing against the projector knockout plate and becoming damaged.
Installing a Permanent Connection
Guidelines:
A 30-32A double pole, UL listed wall circuit breaker is required. It must be part of the building
installation and easily accessible.
Use 10AWG or 8AWG wiring: The distance between the wall circuit breaker and the projector must
not exceed 20 metres using 10AWG cables or 30 metres using 8AWG cables.
For North American installations, use at least 10AWG copper wires for the connection of the main
AC supply to the projector's ground lug.
Copper or aluminum are acceptable as conductor wiring material to the terminal block.
1. A small electrical access plate is located under the projector in the front right corner. Loosen the two
screws and slide the plate forward to expose the terminal block underneath. See Figure 2-10.
2. Remove the knockout plate located in the bottom right corner of the front bezel. The AC supply is routed
to the terminal block through an appropriate strain relief mounted on this knockout plate.
3. Optional, remove the terminal block for easier wiring (thumbscrews).
2-8
=
1) Certified electrician required. 2) Ground (earth) connection is necessary for
Use an appropriate strain relief connector on the AC supply cable to prevent
Figure 2-10
CP2220 User Manual
020-100420-06 Rev. 1 (03-2011)