Christie Solaria CP2220 User Manual page 101

Hide thumbs Also See for Solaria CP2220:
Table of Contents

Advertisement

Steps to Perform Foot Lamberts Calibration
1. Before starting the Foot Lamberts Calibration measurement process, ensure the lamp is ON and you have
your light meter ready (Figure 3-43). Click the Next button to proceed to the Test Pattern window. If
either of these two conditions are not met, the Next button will be disabled (greyed out) and will not let
you proceed with the calibration.
2. In the Test Pattern window, you need to click the Activate Full White Test Pattern button before
proceeding. (Figure 3-44). NOTE: This procedure will stop any content currently playing on the projector.
Click the Next button to proceed to the Maximum window.
CP2220 User Manual
020-100420-06 Rev. 1 (03-2011)
Figure 3-44 Click to Activate a Full White Test Pattern
Section 3: Operation
3-57